GUIDE TO INSTALLATION AND OPERATION
DNR-101i/111i |
13
3.4 DNR-101i/111i Menu
Home S
(User Configuration load) E
CONF
S E
LOAD
S E [USR1,USR2,USR3,USR4, USR5, USR6]
+ +
-
(User Configuration save) E
SAVE
S E [USR1,USR2,USR3,USR4, USR5, USR6]
-
(Operating mode) E
MODE
S
E[MNR, DNR)
DNR-111i only
+
-
(Temporal filter) E
3D
S
E [0,…,3, …,15) 0 = Off
+
-
(Spatial filter) E
2D
S
E [0,…,8, …,15) 0 = Off
+
-
(Block Artefact Remover) E
BAR
S E
ENA
S E [OFF,ON]
DNR-111i only
+ +
-
E
BLK
S
E[0,...,15] block position
-
(Detail Enhancer) E
DE
S
E[0,…,15) 0 = Off
+
-
(Factory default restore) E
FACT
S E [NO,YES]
Note: The underlined options or values in the menu are the default or reset values. Selecting YES in the
Factory Restore [FACT] menu will reset all parameters to these underlined values.
Legend:
Menu motion:
+ : (plus) move toward the top in the menu tree
- : (minus) move to the bottom in the menu tree
S : (select) move to the right in the menu tree
E : (escape) move to the left in the menu tree
Parameter Adjustments:
+ : (plus) go to the next parameter value
- : (minus) go to the previous parameter value
S : (select) select and save the current parameter value
E : (escape) terminate current adjustment without saving
Kommentare zu diesen Handbüchern