GUIDE TO INSTALLATION AND OPERATION
RCP-200 | 39
6.4 User Defaults
The RCP-200 makes use of the User Defaults feature of the iControl system.
User Defaults is a feature that allows a user to specify a nominal value and a tolerance window for certain types of
parameters. Typically, these parameters are continuously variable within a range of values. Such parameters are
displayed and operated using a slider control in the RCP-200.
The nominal value and tolerance window values for a device, as well as the alarm settings, are entered through its
iControl GUI. The RCP-200 cannot be used to modify them. It can, however, recall them all at once using the Restore
Defaults button [20].
The RCP-200 displays these values in the slider associated with the parameter, and responds to out-of-tolerance
events in a manner that highlights their presence at all times and makes it easy to locate the source of a default value
alarm.
For reference, the procedure for setting these tolerances is described here. This example uses the XVP-3901, but the
process is the same for all devices for which this feature is available the only difference may be the location of the
access point in the device’s iControl GUI.
Configuring User Defaults
From iControl Navigator, open the control panel for the device.
Click on the Factory / Presets button on the left side of the display to open the Factory / Presets control panel.
Click the Config… button in the User Defaults area