Miranda KS-900 Bedienerhandbuch Seite 47

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 92
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 46
GUIDE TO INSTALLATION AND OPERATION
Kaleido-Solo | 43
Loudness chart (dual meter representation)
The color identifies the traces (center section) with their numeric values (left section).
Left section
Refer to EBU R128 or ATSC A/85 specification for more details.
Center section
Graphic representation of short term, integrated measurement and the target value. The time
scale is represented at the bottom of this section. Those traces can be independently shown or
hidden (see section 5.5.2). The “EBU Mode or A85 Mode” is displayed only when the
measurements are compliant to those specifications (see section 5.4.6).
Right section
Meter that represents the momentary measurement.
Loudness chart alarm
When the integrated value goes outside the upper and lower tolerance an alarm is triggered. A red frame will appear
around the loudness chart. You can trigger the GPI out with this alarm (see section 5.9).
Standard
Unit
EBU
Mode
A-85
Mode
Target
Upper/Lower Alarm
Tolerances
Alarm Compliance
EBU MODE G8
LUFS
-23
-22/-24
True
EBU MODE G10
LUFS
-23
-22/-24
True
ATSC A/85
ITU-r BS.1770-1
LKFS
-24
-22/-26
True
ATSC A/85
ITU-r BS.1770-2
LKFS
-24
-22/-26
False (-23/-25)
ARIB
LKFS
-24
-21/-27
False (-23/-25)
Note that the alarm tolerances are not configurable.
Seitenansicht 46
1 2 ... 42 43 44 45 46 47 48 49 50 51 52 ... 91 92

Kommentare zu diesen Handbüchern

Keine Kommentare