GUIDE TO INSTALLATION AND OPERATION
Kaleido-Solo | 35
1st Loudness/2nd Loudness - A-85 Mode
The loudness chart will follow the ATSC A/85 recommendation for the loudness measurement.
A parameter that is not compliant with ATSC A/85 has been changed (e.g.: Target parameter is not
set to -24).
Note that if there are stars in front of the menu name (e.g.: ** A-85 Mode) it means that the measurement
respects the EBU algorithm except parameters that were manually changed. These changes could affect
the results.
1st Loudness/2nd Loudness - Target
This parameter will change the target value in loudness chart. Altering this value will unchecked the EBU or A-85
Mode.
1st Loudness/2nd Loudness - Short-Term Time Window
Changing this parameter affects the short term calculation. Altering this value will unchecked the EBU or A-85 Mode.
The choices are:
1 sec
..
15 sec
1st Loudness/2nd Loudness – Relative Gating
Changing this parameter affects the relative gating calculation. Altering this value will unchecked the EBU or A-85
Mode. The choices are:
-8 dB
-10 dB
Loudness measurement summary
affecting
integrated
measure
Refer to EBU R128 or ATSC A/85 specification for more specific details.